Floor area surveys for planning, licensing and contracts
Know your floor area before the council, the tenant or the buyer does. We report GIA, NIA, IPMS or NDSS figures, each labelled with the standard and edition used, for one fixed price confirmed in writing before we start.
Which floor area do you need?
Each rule treats walls, stairs and low ceilings differently, so tell us the purpose.
Planning and permitted development
Each home’s GIA against the 37 m² minimum and the space standard.
HMO licensing
Every sleeping room measured under the licence rules.
Offices and shops
NIA, the usable area, for lettings, rent reviews and business rates.
Industrial and warehouse
GIA for lettings, service charges and build cost.
Pre-lets and handovers
Measured against the target and tolerance in your agreement for lease.
CIL and existing floorspace
The GIA of buildings to be kept or demolished.
NDSS and permitted development
Since 6 April 2021, every home created under permitted development in England must have at least 37 m² of gross internal area and meet the Nationally Described Space Standard (NDSS). Under Classes G, M, MA, N, O, PA and Q, prior approval floor plans must show the total floor space of each home and the dimensions and use of each room.
Under NDSS, floor below 1.5 m headroom is left out unless it is used only for storage: storage between 0.9 m and 1.5 m counts at 50%, below 0.9 m it does not count, and under-stair storage is taken as 1 m². NDSS also needs a 2.3 m floor to ceiling height over at least 75% of the GIA.
For full planning, NDSS applies where the Local Plan has adopted it. Sefton’s Conversions to Flats and HMOs SPD (2023) sets minimum sizes for converted flats: 25 m² for a studio, 37 m² for one bedroom, 61 m² for two and 74 m² for three. Liverpool’s 2022 Local Plan includes space standards too.
Our NDSS area schedule sets each home’s GIA, bedroom areas and widths, built-in storage and ceiling height against NDSS (March 2015, notes May 2016). Compliance is for the local planning authority to decide.
HMO room sizes
In England, sleeping rooms in a licensed HMO must meet minimum sizes: 6.51 m² for one person aged over 10, 10.22 m² for two people aged over 10, and 4.64 m² for a child under 10. Your council may set larger sizes in its own HMO standards.
In July 2026 a tribunal quashed a Liverpool prohibition order after counting an entrance area the council had left out, taking the bedroom to at least 6.51 m². Each case turns on its facts.
- Every sleeping room: bedroom areas measured for HMO licensing, ignoring floor where the ceiling is below 1.5 m.
- En suites: shown separately, so the council can decide whether to count them.
We measure and report. The council decides on the licence.
Commercial NIA and GIA
Offices and shops are usually let, reviewed and rated on NIA, the usable area. Industrial and warehouse lettings, service charges and build cost usually use GIA. If a client or funder asks for IPMS, we measure on that basis.
Our Area Measurement Report comes with a reliance letter on request. For business rates, the Valuation Office Agency leaves areas under 1.5 m headroom out of GEA and GIA, except under stairways, and shows them separately for NIA.
Existing floorspace for CIL
The Community Infrastructure Levy (CIL) is charged on GIA. Existing floorspace kept, or demolished before completion, can be deducted if part of the building was in lawful use for 6 continuous months in the 3 years before planning permission first permits the development. The council may treat it as zero if it lacks enough information.
We measure the GIA of buildings to be kept or demolished; showing lawful use is for you and your adviser. Sefton has no CIL, so we only quote this where your council charges it.
Minimum area checks for developers and contractors
Catch a shortfall at stud stage, not at handover. A stud or first fix check is an early warning, not the final area, which we measure at practical completion against the target and tolerance.
What is a minimum area clause?
Leases and agreements for lease often set a minimum area, usually a target area with an area tolerance. Heads of terms commonly set how it is measured, a rent adjustment, and a tenant right to withdraw if the area measured after practical completion falls outside the tolerance.
In Kilmartin v Safeway [2006] EWHC 60 (Ch), the building measured about 3 m² over the minimum area, so the tenant was held to the deal, and the court refused an extra ±1% accuracy margin.
What a good clause covers
- The target area and the minimum.
- The basis and edition, such as RICS Code NIA, 6th edition.
- The tolerance band, and what happens outside it.
- When it is measured: practical completion, plus any stage check.
- Who measures, and in what role.
- A reliance letter for the party relying on the figure.
A checklist, not legal advice: your solicitor drafts the clause.
Already using our setting out services? Stage checks can be booked alongside them.
What you receive
Area schedule
Areas in m² and sq ft by unit, room and floor, in Excel.
Marked-up plans
PDF and DWG, showing what was measured.
The basis on every figure
The standard and edition named on each area.
Height bands
Voids, mezzanines, garages and balconies stated separately.
Date, method and tolerance
The survey date, method and instrument, with a stated tolerance.
Signed area statement
With a reliance letter on request, naming you, the purpose and any other party we agree in writing.
Clear limits: we measure and report only, with no planning, legal, title, structural, rating or valuation opinion.
How we measure, with the standard named
The two measurement standards RICS now recognises are IPMS: All Buildings (2023) and the RICS Code of Measuring Practice, 6th edition (May 2015). Every report we issue names the basis and edition used.
A draft 7th edition consultation closed on 13 October 2026; RICS says to keep using the 6th edition until the final version is out. The Code sets no fixed tolerance, so we state ours on every report.
On floor area surveys we record height bands (under 0.9 m, 0.9 m to 1.5 m, 1.5 m to 2.3 m, and 2.3 m and over), so each basis you ask for can be reported separately.
| Rule | Floor under 1.5 m headroom |
|---|---|
| RICS Code GIA | Included |
| RICS Code NIA | Excluded |
| NDSS GIA | Excluded unless used only for storage |
| HMO licence room sizes | Ignored |
| Sefton conversions SPD (2023) | Roof space at 1.5 m or less excluded |
Floor area survey prices
Every job is quoted as one fixed price for the agreed scope, confirmed in writing before we start.
| Service | From, excluding VAT | From, including VAT |
|---|---|---|
| Area schedule added to a booked measured building survey | £75 + VAT per dwelling | £90 per dwelling |
| HMO room size check, up to 6 rooms | £225 + VAT, then £25 + VAT per extra room | £270, then £30 per extra room |
| NDSS area schedule for one dwelling, with the measured plan | £375 + VAT | £450 |
| Commercial NIA or GIA report, up to 250 m² (larger buildings quoted) | £495 + VAT | £594 |
| Handover verification for multi-unit schemes | £45 + VAT per apartment, minimum £495 + VAT per visit | £54 per apartment, minimum £594 per visit |
The final price depends on the building, access and travel. A measured building survey on its own starts from £300 + VAT (£360 including VAT). Fire plans for the same building? See fire plan drawings. For gross internal area in depth, see GIA surveys. See all our survey and setting out prices.
Floor area surveys across the North West
We are based in Crosby, Liverpool L23, and work across the North West:
- Liverpool and Merseyside: Liverpool, the Wirral, Sefton, Knowsley and St Helens.
- Greater Manchester: Manchester, Bolton, Wigan, Trafford and Stockport.
- Lancashire and Cumbria: Preston, Blackburn and South Cumbria.
- Cheshire and North Wales: Chester, Warrington, Crewe and Wrexham.
Which rules apply
The space standard, permitted development and HMO room size rules on this page apply in England. Wales has its own rules. General information, checked in November 2026, not planning or legal advice.
Floor area surveys: common questions
What is the difference between GIA and NIA?
GIA, gross internal area, is the whole floor area inside the perimeter walls, including internal walls, stairs, lift shafts, toilets and plant rooms. NIA, net internal area, is the usable area: it leaves out toilets, stairs, lift lobbies, plant rooms, common parts, structural walls, columns and areas under 1.5 m headroom.
Can you tell me if my flat meets the space standard?
We measure it and set the figures against the Nationally Described Space Standard. Compliance is for the local planning authority to decide, on a planning or prior approval application.
Do areas with low ceilings count?
It depends on the rule. For areas under 1.5 m headroom, the RICS Code counts them in GIA but not NIA, NDSS leaves them out unless used only for storage, and HMO room sizes ignore them. We report each basis you ask for separately.
Can you measure rooms for an HMO licence?
Yes. We measure each sleeping room under the licence rules, ignoring floor where the ceiling is under 1.5 m and showing en suites separately. Checks for up to 6 rooms start from £225 + VAT (£270 including VAT).
Can I rely on your figures in a lease or sale?
Only on the terms of our reliance letter, issued on request, naming you, the purpose and any other party we agree in writing. If your contract says who must measure, or which standard and edition to use, send us the clause first.
Are you RICS regulated?
No. We measure using the definitions in the RICS Code of Measuring Practice and IPMS, and we name the standard on every report.
How quickly can you visit and report?
It depends on the building and access. We give target visit and report dates in writing when we quote.
Need a floor area survey?
Send the address and what the figures are for, and we’ll quote one fixed price.