Fire plan drawings for flats and workplaces in Liverpool and the North West
Fire and rescue service plans, escape and evacuation plan drawings for display, and fire precautions plans, drawn from a measured survey of your building or from your existing drawings. Fire safety is assessed by a competent fire risk assessor or fire engineer, and we never carry out fire risk assessments. Every job is quoted at a fixed price in writing before we start.
We draw. Your fire risk assessor assesses.
Our survey team measures the building and records where the fire equipment is: lifts, rising mains, smoke vents, sprinkler valves, alarm panels, the secure information box and fire appliance access. We record where it is, not whether it works, then draw clear plans in the format the job needs.
What we do not do
We do not carry out or review fire risk assessments or write fire or evacuation strategies. We do not decide escape routes, lift designations, compartment lines, fire door ratings or travel distances: these go on our drawings only when supplied in writing. We do not judge whether a building or its fire precautions are adequate, inspect or test fire safety equipment, lifts or the secure information box, or carry out the regulation 4 or 7 checks. We do not sign or submit plans as the responsible person.
Fire service plans for high-rise residential buildings
Since 23 January 2023, high-rise residential buildings in England must have floor plans and a single page building plan, with a hard copy in the secure information box and electronic copies sent to the fire and rescue service. That means buildings with two or more flats that are at least 18 m high or have at least 7 storeys (Fire Safety (England) Regulations 2022, regulations 6 and 11; see the government’s fact sheet). This is a summary, not legal advice: the responsible person should confirm what applies to their building.
What the plans must show
- Floor plans: one per floor, although identical floors may share a plan that says which floors it covers. Together they show where all the lifts are and say which are firefighting or evacuation lifts, plus key firefighting equipment: dry and wet rising main inlets and outlets, smoke control systems and suppression systems.
- Building plan: one page showing the surroundings and fire appliance access, the building’s use, dimensions, storeys and basements, any maisonettes or scissor section flats, and where the dry and wet rising main inlets, the sprinkler shut-off, smoke control and evacuation alert controls, access points, secure information box, firefighting shafts and main stairways are.
- Standard: government guidance says each floor plan should be a “reasonably accurate reflection” of the floor and kept simple. The regulations set no scale and do not say who must prepare them.
How we draw them
We follow the plan guidance in the FIA and NFCC Code of Practice for Secure Information Boxes, version 4 (April 2026), with local fire and rescue service symbols where they exist:
- A3 sheets, legible at A3, with the key on the left-hand side.
- An orientation plan with the address, date, key and the author’s name, as the code asks.
- Compartment lines in red, taken from your fire strategy or assessment.
- Two encapsulated A3 sets of every plan for the box.
As author we are responsible for the accuracy of what we recorded on our survey date or, without a visit, for drawing faithfully from your drawings. We are not responsible for fire safety information from others, which each sheet credits to its source.
We also supply PDF and DWG files for the responsible person to submit; acceptance is for the fire and rescue service.
Since 6 April 2026, buildings in England with two or more flats that are at least 18 m high or have at least 7 storeys, or are over 11 m high with a simultaneous evacuation strategy, also need a building emergency evacuation plan (BEEP) under the Residential Evacuation Plans Regulations 2025. We do not write BEEPs or residents’ personal emergency evacuation plans, but can supply plan backgrounds, which never show which residents need help.
Escape plans for display
“You are here” escape and evacuation plan drawings for staff, visitors and residents, at A4 or A3 for each plan position, laid out in the style of BS ISO 23601:2020 with ISO 7010 safety symbols.
Your fire risk assessor sets the escape routes and plan positions and confirms them in writing; we draw them and do not choose or change routes. BS ISO 23601 is not intended to cover plans used by external safety services such as the fire and rescue service, so fire service plans are separate drawings.
Fire precautions plans for your fire risk assessment
In non-domestic premises in England and Wales, the responsible person must carry out a suitable and sufficient fire risk assessment and keep it under review (Fire Safety Order 2005, article 9). In England, since 1 October 2023 the whole assessment and all fire safety arrangements must be recorded, whatever the number of employees (Building Safety Act 2022, section 156).
The law does not require a drawing, but the Home Office guide for offices and shops says a simple line drawing of the fire precautions “can be helpful”. We draw it from your assessment, with the exits, call points, extinguishers, fire doors and assembly point.
For fire risk assessors and alarm installers
We can draw escape plans, fire precautions plans and fire alarm zone plans for fire risk assessors, alarm installers and managing agents, unbranded or in your branding. Every sheet keeps our note of the survey date or source drawings and who supplied the fire safety information.
- From your drawings: no site visit, from £75 + VAT per floor. We do not check your drawings against the building, so the plan is only as accurate as they are, and each sheet names the drawings used. With no usable drawings, our survey team measures first.
- Zone plans: drawn from the zone and device information you or the installer supply. Under BS 5839-1:2025, a missing, out of date or inaccurate zone plan counts as a “major non-conformity” (FIA guidance). BS 5839-1 is a code of practice, not law.
What we need from you
- The fire risk assessment, any fire strategy and any existing drawings, even old ones.
- O&M manuals and the Regulation 38 fire safety information from handover.
- Which floors need plans, and access to plant rooms, risers and the roof.
You check the draft and confirm it in writing before final issue. Each drawing notes our survey date or the drawings used, who supplied the fire safety information, and that it is not a fire risk assessment or fire strategy. The responsible person should check it before use or submission.
Fire plan drawing prices
Each fixed price quote lists what is included and any extras, such as a return visit if access is not available.
| What you need | Starting price |
|---|---|
| Displayed escape plan, one floor and one plan position, site visit included | From £345 + VAT |
| Each extra floor or plan position | From £125 + VAT |
| Trade plan from your existing drawings, no site visit, not checked against the building | From £75 + VAT per floor |
| High-rise fire service plan pack, measured, with building and orientation plans and A3 box sets | From £950 + VAT per building, plus from £150 + VAT per floor plan |
| Reformat existing drawings to the fire service format (not checked on site unless your quote includes a visit) | From £395 + VAT per building |
| Revision after a change | From £75 + VAT per sheet |
| Annual plan review: we check the plans still match the building (not a fire safety review, no automatic renewal) | From £195 + VAT per building per year |
All prices exclude VAT, added at the standard rate. For full floor plans and elevations for design work, see our measured building surveys or all our survey and setting out prices.
Areas we cover
We are based in Crosby, Liverpool L23, and cover Liverpool and Merseyside, Greater Manchester, Lancashire and Cumbria, and Cheshire and North Wales.
Buildings outside England
The high-rise plan rules on this page apply in England. Wales and Scotland have their own rules, so for buildings there, tell us what your fire risk assessor or fire and rescue service has asked for, and we will quote.
Fire plan drawings: common questions
Do I legally need fire plans?
High-rise residential buildings in England do: those with two or more flats that are at least 18 m high or have at least 7 storeys. For other premises a drawing is not generally a legal requirement, although Home Office guidance says a simple drawing of your fire precautions can be helpful. Ask your fire risk assessor. This is a general summary, not legal advice.
Can you prepare plans in Merseyside Fire and Rescue Service’s format?
Yes. We follow Merseyside Fire and Rescue Service’s published guidance, but we are not connected with or approved by any fire and rescue service, and each service decides whether plans meet its needs.
Do identical floors need separate plans?
In England, the Fire Safety (England) Regulations 2022 allow one plan for floors that are the same in all material respects, if it says which floors it covers, but the FIA and NFCC code prefers one plan per floor. Your quote says which approach we will use.
Do fire plans have to be measured?
No. For high-rise residential buildings in England, government guidance asks for a reasonably accurate plan of each floor, and the regulations set no scale. When we visit, our plans reflect the building on our survey date; plans from your drawings are only as accurate as those drawings.
How often do fire plans need updating?
In England, high-rise residential plans must be updated as soon as reasonably practicable after any change to the layout of the building or the location of key firefighting equipment. The FIA and NFCC code also recommends an annual review as good practice.
Need fire plans drawn?
Tell us about the building, which plans you need and what fire safety information you hold, and we’ll come back with a fixed price in writing.